WEKO3
アイテム
{"_buckets": {"deposit": "02afe2e4-a967-48a0-b810-29dee27a4870"}, "_deposit": {"created_by": 13, "id": "53", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "53"}, "status": "published"}, "_oai": {"id": "oai:kurume-it.repo.nii.ac.jp:00000053", "sets": ["21"]}, "author_link": ["96", "94", "95", "92", "93", "91"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-03-17", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "36", "bibliographicPageEnd": "12", "bibliographicPageStart": "9", "bibliographic_titles": [{"bibliographic_title": "久留米工業大学研究報告"}]}]}, "item_10002_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Nucleate pool boiling heat transfer coefficients have been measured when a surface - active agent was added into water. Those have been measured on a heated wire that PEEK (Poly Ether ·Ether ·Keton) resin was coated in ammonia. The experiment has been carried out using a thermosyphon with a plain heated surface and a pool boiling vessel with a heated fine wire. The effect of the surface - active agent and PEEK resin coating on the nucleate boiling heat transfer coefficient and time variation of the nucleate boiling heat transfer coefficient were investigated experimentally for the surfactant concentration, CS=0 and 1000 ppm. The result shows that the nucleate boiling heat transfer coefficient never changes for more than a month in pure water and in ammonia with the heated wire coated by PEEK resin. On the other\nhand, the boiling heat transfer coefficient decreases gradually till the end of operation in water with the surfactant.", "subitem_description_type": "Other"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0389-6897", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "井上, 利明"}, {"creatorName": "イノウエ, トシアキ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "91", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "黒田, 光"}, {"creatorName": "クロダ, ヒカル", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "92", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "真鶴, 哲郎"}, {"creatorName": "マズル, テツロウ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "93", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "INOUE, Toshiaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KURODA, Hikaru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "95", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MAZURU, Tetsurou", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "96", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-03-12"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "inoue _kurumeko_No.36-3.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 1400000.0, "url": {"label": "水およびアンモニアの沸騰熱伝達とその経年変化に及ぼす 界面活性剤とPEEK 樹脂コーティングの影響", "url": "https://kurume-it.repo.nii.ac.jp/record/53/files/inoue _kurumeko_No.36-3.pdf"}, "version_id": "628da4ae-c58c-4f66-9b52-2811d6ee5d76"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Nucleate Boiling", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Heat Transfer", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Surface-Active Agent", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Secular Change", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "PEEK Resin Coating", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "水およびアンモニアの沸騰熱伝達とその経年変化に及ぼす 界面活性剤とPEEK 樹脂コーティングの影響", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "水およびアンモニアの沸騰熱伝達とその経年変化に及ぼす 界面活性剤とPEEK 樹脂コーティングの影響"}, {"subitem_title": "Effect of a Surface-Active Agent and PEEK Resin Coating on Nucleate Boiling Heat Transfer and its Secular Change in Water and Ammonia", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "13", "path": ["21"], "permalink_uri": "https://kurume-it.repo.nii.ac.jp/records/53", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-03-12"}, "publish_date": "2018-03-12", "publish_status": "0", "recid": "53", "relation": {}, "relation_version_is_last": true, "title": ["水およびアンモニアの沸騰熱伝達とその経年変化に及ぼす 界面活性剤とPEEK 樹脂コーティングの影響"], "weko_shared_id": -1}
水およびアンモニアの沸騰熱伝達とその経年変化に及ぼす 界面活性剤とPEEK 樹脂コーティングの影響
https://kurume-it.repo.nii.ac.jp/records/53
https://kurume-it.repo.nii.ac.jp/records/53c0d1e0d9-c39d-41c8-a3c2-50d8a8c43a90
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-12 | |||||
タイトル | ||||||
タイトル | 水およびアンモニアの沸騰熱伝達とその経年変化に及ぼす 界面活性剤とPEEK 樹脂コーティングの影響 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Effect of a Surface-Active Agent and PEEK Resin Coating on Nucleate Boiling Heat Transfer and its Secular Change in Water and Ammonia | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Nucleate Boiling | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Heat Transfer | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Surface-Active Agent | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Secular Change | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | PEEK Resin Coating | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
井上, 利明
× 井上, 利明× 黒田, 光× 真鶴, 哲郎× INOUE, Toshiaki× KURODA, Hikaru× MAZURU, Tetsurou |
|||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Nucleate pool boiling heat transfer coefficients have been measured when a surface - active agent was added into water. Those have been measured on a heated wire that PEEK (Poly Ether ·Ether ·Keton) resin was coated in ammonia. The experiment has been carried out using a thermosyphon with a plain heated surface and a pool boiling vessel with a heated fine wire. The effect of the surface - active agent and PEEK resin coating on the nucleate boiling heat transfer coefficient and time variation of the nucleate boiling heat transfer coefficient were investigated experimentally for the surfactant concentration, CS=0 and 1000 ppm. The result shows that the nucleate boiling heat transfer coefficient never changes for more than a month in pure water and in ammonia with the heated wire coated by PEEK resin. On the other hand, the boiling heat transfer coefficient decreases gradually till the end of operation in water with the surfactant. |
|||||
書誌情報 |
久留米工業大学研究報告 号 36, p. 9-12, 発行日 2014-03-17 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0389-6897 |